![Siemens SINAMICS S Series Скачать руководство пользователя страница 421](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427421.webp)
List of parameters
Parameters
1-421
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
The macros in the specified directory are displayed in r8573. r8573 is not in the Expert list of the commissioning
software.
Macros available as standard are described in the technical documentation of the particular product.
CI: Connector Input
Description:
Sets the signal source for toggling between speed and torque control.
Dependency:
The input connectors to enter the torque are provided using p1511, p1512 and p1513.
Refer to: p1300
Caution:
If the closed-loop torque control is not activated (p1300) and a change is made to closed-loop torque control
(p1501), OFF1 (p0840) does not have its own braking response but pulse cancelation when standstill is detected
(p1226, p1227).
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
0 signal: Closed-loop speed control
1 signal: Closed-loop torque control
Description:
Sets the signal source for toggling between velocity and force control.
Dependency:
The input connectors to enter the force are provided using p1511, p1512 and p1513.
Refer to: p1300
Caution:
If the closed-loop force control is not activated (p1300) and a change is made to closed-loop force control (p1501),
OFF1 (p0840) does not have its own braking response but pulse cancelation when standstill is detected (p1226,
p1227).
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
0 signal: Velocity control
1 signal: Force control
Description:
Sets the signal source for the torque setpoint for torque control.
Note:
A change is made to closed-loop torque control if, in p1300, closed-loop torque control was selected or if the selec-
tion was made using the changeover source in p1501.
it is also possible to change over in operation using p1501.
p1501[0...n]
BI: Change over between closed-loop speed/torque control / Changeov n/M_ctrl
SERVO, VECTOR
(n/M)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
2520, 5060,
6060
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
0
p1501[0...n]
BI: Changeover velocity/force control / Changeov n/F_ctrl
SERVO (Lin)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
2520, 5060,
6060
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
0
p1503[0...n]
CI: Torque setpoint / M_set
VECTOR (n/M)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...