Parameters
List of parameters
1-1012
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the transition time from STOP F to STOP B.
Dependency:
Refer to: C01711
Note:
A change only becomes effective after a POWER ON.
Description:
Sets the delay time for the safe pulse cancelation after STOP B.
Dependency:
Refer to: p9560
Refer to: C01701
Note:
A change only becomes effective after a POWER ON.
Description:
Sets the time after which the pulses must have been canceled when initiating the test stop.
Dependency:
Refer to: C01798
Note:
A change only becomes effective after a POWER ON.
Description:
Sets the maximum time for the acceptance test mode.
If the acceptance test mode takes longer than the selected time limit, then the mode is automatically terminated.
Dependency:
Refer to: C01799
Note:
A change only becomes effective after a POWER ON.
p9555
SI motion transition time STOP F to STOP B (Control Unit) / SI Mtn t F->B CU
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
2825
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [ms]
600000.00 [ms]
0.00 [ms]
p9556
SI motion pulse cancelation delay time (Control Unit) / SI Mtn IL t_del CU
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
2825
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [ms]
600000.00 [ms]
100.00 [ms]
p9557
SI motion pulse cancelation test time (Control Unit) / SI Mtn IL t_test
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [ms]
10000.00 [ms]
100.00 [ms]
p9558
SI motion acceptance test mode time limit (Control Unit) / SI Mtn t accept
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
5000.00 [ms]
100000.00 [ms]
40000.00 [ms]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...