Parameters
List of parameters
1-516
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the identified high load inertia.
Dependency:
Refer to: p0341, p0342, p1498, p1959, p1960
Description:
Displays the determined moment of inertia of the drive.
After it has been determined, the value is transferred to p0341, p0342.
Dependency:
Refer to: p0341, p0342, p1959
Refer to: F07984
Description:
Displays the vibration frequencies determined by the vibration test.
Index:
[0] = Frequency low
[1] = Frequency high
Dependency:
Refer to: p1959
Refer to: F07985
Description:
Displays the standard deviations of the vibration frequencies determined by the vibration test
Index:
[0] = Standard deviation of low frequency
[1] = Standard deviation of high frequency
Dependency:
Refer to: p1959
Refer to: F07985
r1969
High load inertia identified / High load inert id
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
27_1
Unit selection:
p0100
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- [kg]
- [kg]
- [kg]
r1969
Speed_ctrl_opt moment of inertia determined / n_opt M_inert det
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
25_1
Unit selection:
p0100
Not for motor type:
PEM, REL
Expert list:
1
Min Max
Factory
setting
- [kgm²]
- [kgm²]
- [kgm²]
r1970[0...1]
Speed_ctrl_opt vibration test vibration frequency determined / n_opt f_vibration
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL
Expert list:
1
Min Max
Factory
setting
- [Hz]
- [Hz]
- [Hz]
r1971[0...1]
Speed_ctrl_opt vibration test standard deviation determined / n_opt std. deviat.
VECTOR (n/M)
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL
Expert list:
1
Min Max
Factory
setting
- [Hz]
- [Hz]
- [Hz]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...