![Siemens SINAMICS S Series Скачать руководство пользователя страница 845](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427845.webp)
List of parameters
Parameters
1-845
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the edge status for digital input 16 ... 23 of terminal module 15 (TM15).
Assignment of the digital inputs to the bits:
DI 16: r4313.1 ... 0
DI 17: r4313.3 ... 2
DI 18: r4313.5 ... 4
DI 19: r4313.7 ... 6
DI 20: r4313.9 ... 8
DI 21: r4313.11 ... 10
DI 22: r4313.13 ... 12
DI 23: r4313.15 ... 14
Possible edge states:
Bit x, y = 0, 0 --> no edge detection
Bit x, y = 0, 1 --> 1st edge detected
Bit x, y = 1, 0 --> 2nd edge detected
Bit x, y = 1, 1 --> both edges detected
Note:
DI: Digital input
Description:
Displays the time when detecting the 1st and 2nd edge for digital input 0 of terminal module 17 (TM17).
The two times are specified as 16 bit values with a resolution of 0.25 µs.
Note:
DI: Digital input
Description:
Displays the time when detecting the 1st and 2nd edge for digital input 0 of terminal module 15 (TM15).
The two times are specified as 8 bit values with a resolution of 64 µs.
Note:
DI: Digital input
r4313
TM15 edge status digital input 16 ... 23 / TM15 EdgSt DI16-23
TM15
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r4350
TM17 edge times digital input 0 / TM17 edge_t DI 0
TM17
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r4350
TM15 edge times digital input 0 / TM15 edge_t DI 0
TM15
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...