List of parameters
Parameters
1-995
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the axis type (linear axis or rotary axis/spindle).
Values:
0:
Linear axis
1:
Rot axis/spindle
Note:
For the commissioning software, after changing over the axis type, the units dependent on the axis type are only
updated after a project upload.
A change only becomes effective after a POWER ON.
Description:
Setting to enable the function "Safe Cam" (SCA).
Dependency:
Refer to: p9501
Refer to: F01686
p9502
SI motion axis type (Control Unit) / SI Mtn axis type
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p9503
SI motion SCA (SN) enable (Control Unit) / SI Mtn SCA enab
SERVO, VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Enable SCA1 (SN1)
Enable
Inhibit
-
01
Enable SCA2 (SN2)
Enable
Inhibit
-
02
Enable SCA3 (SN3)
Enable
Inhibit
-
03
Enable SCA4 (SN4)
Enable
Inhibit
-
04
Enable SCA5 (SN5)
Enable
Inhibit
-
05
Enable SCA6 (SN6)
Enable
Inhibit
-
06
Enable SCA7 (SN7)
Enable
Inhibit
-
07
Enable SCA8 (SN8)
Enable
Inhibit
-
08
Enable SCA9 (SN9)
Enable
Inhibit
-
09
Enable SCA10 (SN10)
Enable
Inhibit
-
10
Enable SCA11 (SN11)
Enable
Inhibit
-
11
Enable SCA12 (SN12)
Enable
Inhibit
-
12
Enable SCA13 (SN13)
Enable
Inhibit
-
13
Enable SCA14 (SN14)
Enable
Inhibit
-
14
Enable SCA15 (SN15)
Enable
Inhibit
-
15
Enable SCA16 (SN16)
Enable
Inhibit
-
16
Enable SCA17 (SN17)
Enable
Inhibit
-
17
Enable SCA18 (SN18)
Enable
Inhibit
-
18
Enable SCA19 (SN19)
Enable
Inhibit
-
19
Enable SCA20 (SN20)
Enable
Inhibit
-
20
Enable SCA21 (SN21)
Enable
Inhibit
-
21
Enable SCA22 (SN22)
Enable
Inhibit
-
22
Enable SCA23 (SN23)
Enable
Inhibit
-
23
Enable SCA24 (SN24)
Enable
Inhibit
-
24
Enable SCA25 (SN25)
Enable
Inhibit
-
25
Enable SCA26 (SN26)
Enable
Inhibit
-
26
Enable SCA27 (SN27)
Enable
Inhibit
-
27
Enable SCA28 (SN28)
Enable
Inhibit
-
28
Enable SCA29 (SN29)
Enable
Inhibit
-
29
Enable SCA30 (SN30)
Enable
Inhibit
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...