For the direct measuring probe evaluation, the DP clock cycle must be integer multiple of the position controller
clock cycle.
Description:
Sets the behavior of the position actual value preprocessing for the position controller for a DDS changeover.
Re p2519 = 1:
In the following cases, for a DDS changeover, the actual position actual value becomes invalid and the reference
point is reset:
- the EDS effective for the closed-loop position control changes.
- the encoder assignment changes (p2502).
- the mechanical relationships change (p2503 ... p2506).
- the direction of rotation changes (p1821).
For absolute encoders, the status of the adjustment (p2507) is also reset if the same absolute encoder remains
selected for the closed-loop position control, but the mechanical relationships or the direction of rotation have
changed.
In the run state, in addition, a fault message (F07494) is generated.
Notice:
The remaining setting values are intended for expanded functionality.
Note:
The behavior for a DDS changeover is determined using the value of p2519 in the target data set.
Description:
Displays the encoder control word generated by the position actual value preprocessing.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: p0480
Note:
When the function module "basic positioner" (r0108.4 = 1) is activated, the following BICO interconnection is estab-
lished:
CI: p0480[0] = r2520[0], CI: p0480[1] = r2520[1] and CI: p0480[2] = r2520[2]
p2519[0...n]
LR position actual value preprocessing config. DDS changeover / s_act config DDS
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Integer16
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 5
1
r2520[0...2]
CO: LR Position actual value preprocessing, encoder control word /
ActVal_prep STW
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
4010
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Request function 1
Yes
No
-
01
Request function 2
Yes
No
-
02
Request function 3
Yes
No
-
03
Request function 4
Yes
No
-
04
Request command bit 0
Yes
No
-
05
Request command bit 1
Yes
No
-
06
Request command bit 2
Yes
No
-
07
Mode flying measurement / search for refer-
ence
Flying measurement
Reference marks
-
13
Request absolute value cyclic
Yes
No
-
14
Request parking encoder
Yes
No
-
15
Request acknowledge encoder fault
Yes
No
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...