List of parameters
Parameters
1-867
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Selects the first signal to be traced.
For trace with a physical address (p4780), the data type of the signal to be traced (recorded) is set here.
Index:
[0] = Trace 0
[1] = Trace 1
Description:
Selects the second signal to be traced.
For trace with a physical address (p4781), the data type of the signal to be traced (recorded) is set here.
Index:
[0] = Trace 0
[1] = Trace 1
Description:
Selects the third signal to be traced.
For trace with a physical address (p4782), the data type of the signal to be traced (recorded) is set here.
Index:
[0] = Trace 0
[1] = Trace 1
Description:
Selects the fourth signal to be traced.
For trace with a physical address (p4783), the data type of the signal to be traced (recorded) is set here.
Index:
[0] = Trace 0
[1] = Trace 1
p4730[0...1]
Trace record signal 0 / Trace record sig 0
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
- -
0
p4731[0...1]
Trace record signal 1 / Trace record sig 1
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
- -
0
p4732[0...1]
Trace record signal 2 / Trace record sig 2
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
- -
0
p4733[0...1]
Trace record signal 3 / Trace record sig 3
CU_CX32, CU_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
0
Min Max
Factory
setting
- -
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...