Parameters
List of parameters
1-394
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the numerator damping for velocity setpoint filter 2 (general filter).
Dependency:
Refer to: p1414, p1421
Note:
This parameter is only effective if the velocity filter is set as a general filter.
Description:
Sets the dead time to symmetrize the speed setpoint for active torque pre-control.
The selected multiplier refers to the speed controller clock cycle (dead time= p1428 * p0115[1]).
Dependency:
In conjunction with p1429, this parameter can simulate the characteristics of how the torque is established (dynamic
response of closed current control loop).
For VECTOR (r0107) the following applies:
The parameter is only effective if the acceleration model is supplied using external acceleration signals (p1400.2 =
1). For p1400.2 = 0, a fixed dead time is used.
Refer to: p1429, p1511
Description:
Sets the dead time to symmetrize the velocity setpoint for active force pre-control.
The selected multiplier refers to the velocity controller clock cycle (dead time= p1428 * p0115[1]).
Dependency:
In conjunction with p1429, this parameter can simulate the characteristics of how the force is established (dynamic
response of closed current control loop).
Refer to: p1429, p1511
Description:
Sets the time constant (PT1) for symmetrizing the speed setpoint for active torque pre-control.
p1426[0...n]
Velocity setpoint filter 2 numerator damping / v_set_filt 2 D_n
SERVO (Lin)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5020
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.000 10.000
0.700
p1428[0...n]
Speed pre-control balancing dead time / n_prectrBal t_dead
SERVO, VECTOR
(n/M)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5030, 5042,
5210, 6031
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.0 2.0
0.0
p1428[0...n]
Velocity pre-control balancing dead time / n_prectrBal t_dead
SERVO (Lin)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5030, 5042,
5210
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.0 2.0
0.0
p1429[0...n]
Speed pre-control balancing time constant / n_prectr bal T
SERVO, VECTOR
(n/M)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5030, 5042,
5210, 6031
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [ms]
10000.00 [ms]
0.00 [ms]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...