Parameters
List of parameters
1-858
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the sensor type of the second temperature sensor for the motor temperature monitoring.
The parameter can only be changed for SME120, SME125, CU310 and CUA32.
Values:
0:
No sensor available
10:
PTC fault
11:
PTC alarm
12:
PTC alarm and timer stage
20:
KTY84
30:
Bimetallic NC contact fault
31:
Bimetallic NC contact alarm
32:
Bimetallic NC contact alarm and timer stage
Dependency:
Refer to: r0458, p0600, p0601
Note:
Terminals for KTY84: X200.1, X200.2
PTC thermistor: Tripping resistance = 1650 Ohm
Description:
Sets the sensor type of the third temperature sensor for the motor temperature monitoring.
The parameter can only be changed for SME120, SME125.
Values:
0:
No sensor available
10:
PTC fault
11:
PTC alarm
12:
PTC alarm and timer stage
20:
KTY84
30:
Bimetallic NC contact fault
31:
Bimetallic NC contact alarm
32:
Bimetallic NC contact alarm and timer stage
Dependency:
Refer to: r0458, p0600, p0601
Note:
Terminals for PTC triplet and bimetallic: X200.3, X200.4
PTC thermistor: Tripping resistance = 1650 Ohm
Description:
Sets the sensor type of the fourth temperature sensor for the motor temperature monitoring.
The parameter can only be changed for SME120, SME125.
p4601[0...n]
Motor temperature sensor 2 sensor type / MotTemp_sens typ 2
SERVO, VECTOR
Can be changed:
C2(3), U, T
Calculated:
-
Access level:
2
Data type:
Integer16
Dynamic index:
EDS, p0140
Func. diagram:
8016
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 32
0
p4602[0...n]
Motor temperature sensor 3 sensor type / MotTemp_sens typ 3
SERVO, VECTOR
Can be changed:
C2(3), U, T
Calculated:
-
Access level:
2
Data type:
Integer16
Dynamic index:
EDS, p0140
Func. diagram:
8016
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 32
0
p4603[0...n]
Motor temperature sensor 4 sensor type / MotTemp_sens typ 4
SERVO, VECTOR
Can be changed:
C2(3), U, T
Calculated:
-
Access level:
2
Data type:
Integer16
Dynamic index:
EDS, p0140
Func. diagram:
8016
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 32
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...