Parameters
List of parameters
1-688
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Setting to invert actual values.
Description:
Setting to invert actual values.
Description:
Motor moment of inertia (without load) measured from the motor identification.
Description:
Sets the high moments of inertia (without load).
Note:
The parameter is automatically preset for motors from the motor list (p0301).
SERVO:
p0341 * p0342 + p1498 influence the speed/torque pre-control in sensorless operation.
p3031
Motor identification - encoder inversion actual value / MotId EncInvActVal
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Invert speed actual value
Yes
No
4710,
4715
01
Invert position actual value
Yes
No
4704
p3031
Motor identification - encoder inversion actual value / MotId EncInvActVal
SERVO (Lin)
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Invert velocity actual value
Yes
No
4710,
4715
01
Invert position actual value
Yes
No
4704
p3041
Motor identification - moment of inertia / MotId M_mom inert
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
25_1
Unit selection:
p0100
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.000000 [kgm²]
100000.000000 [kgm²]
0.000000 [kgm²]
p3041
Motor weight / Mot weight
SERVO (Lin)
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
27_1
Unit selection:
p0100
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.000000 [kg]
10000.000000 [kg]
0.000000 [kg]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...