List of parameters
Parameters
1-767
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
When motor rating plate parameters are changed, the final display is reset. When setting the individual bits, all of
the most significant bits are reset.
Bit 00 = Complete calculation of the motor/control parameters (p0340 = 1, p3900 > 0).
Bit 02 = Motor data identification (p1910 = 1) successfully completed.
Bit 03 = Rotating measurement (p1960 = 1, 2) successfully completed.
Bit 04 = Motor encoder adjustment (p1990 = 1) successfully completed.
Bit 15 = Equivalent circuit diagram parameters of the motor were subsequently manually changed.
Description:
Displays the data determined from the motor identification and that has been accepted.
Dependency:
Refer to: r3925
Description:
Successfully completed component of the last motor data identification carried out.
r3927[0...n]
Motor data identification determined data (induction motor) / MotID det dat ASM
SERVO
Can be changed:
-
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Unsigned32
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
p0350 accepted
Yes
No
-
01
p0354 accepted
Yes
No
-
02
p0356 accepted
Yes
No
-
03
p0358 accepted
Yes
No
-
04
p0360 accepted
Yes
No
-
05
p0320 accepted
Yes
No
-
06
p0410 accepted
Yes
No
-
12
p1715 accepted
Yes
No
-
13
p1717 accepted
Yes
No
-
14
p1590 accepted
Yes
No
-
15
p1592 accepted
Yes
No
-
22
p0341 accepted
Yes
No
-
r3927[0...n]
Motor data identification control word / MotID STW
VECTOR
Can be changed:
-
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
Unsigned16
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Stator inductance estimate no measure-
ment
Yes
No
-
01
Cl.-loop current control w/ dead-beat con-
troller
Yes
No
-
02
Rotor time constant estimate no measure-
ment
Yes
No
-
03
Leakage inductance estimate no measure-
ment
Yes
No
-
04
Activates the identification dynamic leak-
age inductance
Yes
No
-
05
Determine Tr and Lsig evaluation in the time
range
Yes
No
-
06
Activates vibration damping
Yes
No
-
07
De-activates the vibration detection
Yes
No
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...