![Siemens SINAMICS S Series Скачать руководство пользователя страница 1721](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_12654271721.webp)
List of faults and alarms
Faults and Alarms
3-1721
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
0xBA: Action: All slave DOs at the original state - error: Master not in state 0xC5.
0xC5: Action: Return to start state, test stop completed on the slave side. Error: Master not in state 0xD0.
Test stop step cc for master (hexadecimal):
0x0A: No actions - error: Slave not in initial state 0x00.
0x15: No actions - error: Slave not in initial state 0x0A.
0x20: No actions - error: F-DIs 0...4 of the slave do not correspond with those of the master (expected: level 0) or
slave not in state 0x15.
0x2B: No actions - error: Slave not in initial state 0x20.
0x36: No actions - error: F-DIs 0...5 of the slave do not correspond with those of the master (expected: level 0) or
slave not in state 0x2B.
0x41: Action: All master DOs at OFF - error: Slave not in state 0x36.
0x4C: Action: All master DOs at OFF - error: Slave not in state 0x41.
0x57: Action: All master-DOs at ON - error: Status of DI 20...23 of the slave does not correspond to the expected
state (24V) or the slave not in state 0x4C.
0x62: Action: All master DOs at ON - error: Slave not in initial state 0x57.
0x6D: Action: All master-DOs at ON - error: State of DI 20...23 of the slave does not correspond to the expected state
(0V) or the slave not in state 0x62.
0x78: Action: All master DOs at ON - error: Slave not in state 0x6D.
0x83: Action: All master-DOs at OFF - error: State of DI 20...23 of the slave does not correspond to the expected
state (0V) or the slave not in state 0x78.
0x8E: Action: All master DOs at OFF - error: Slave not in state 0x83.
0x99: Action: All master-DOs at OFF - error: State of DI 20...23 of the slave does not correspond to the expected
state (0V) or the slave not in state 0x8E.
0xA4: Action: All master DOs at OFF - error: Slave not in state 0x99.
0xAF: Action: All master-DOs at OFF - error: Status of DI 20...23 of the slave does not correspond to the expected
state (24V) or the slave not in state 0xA4.
0xBA: Action: All master DOs at the original state - error: Slave not in state 0xAF.
0xC5: Action: All master DOs at the original state - error: Slave not in state 0xBA.
0xD0: Wait for the end of the test stop and return to the start state
Note: A check of the switching state of the F-DIs and DIs always refers to the switching operation of the previous
state. The actions in one state are always only carried out after the actual state has been checked.
Remedy:
Check the wiring of the F-DIs and F-DOs and restart the test stop. The fault is withdrawn if the test stop is success-
fully completed.
A35014
TM54F: Test stop required
Drive object:
A_INF, B_INF, CU_LINK, DMC20, SERVO, S_INF, TB30, TM15, TM15DI_DO, TM17, TM31, TM41, TM54F_MA,
TM54F_SL, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
- after powering-up the drive, a test stop has still not been carried out.
- a new test stop is required after commissioning.
- the time to carry out the forced checking procedure (test stop) has expired (p10003).
Remedy:
Initiate test stop (BI: p10007).
A35015
TM54F: Communication with drive not established
Drive object:
A_INF, B_INF, CU_LINK, DMC20, SERVO, S_INF, TB30, TM15, TM15DI_DO, TM17, TM31, TM41, TM54F_MA,
TM54F_SL, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
Cyclic communication of one or several drives with the Terminal Module 54F (TM54F) is not active.
Fault value (r0949, interpret binary):
Bit 0 = 1: No communication with drive 1.
...
Bit 5 = 1: No communication with drive 6.
For fault value = 0, the following applies:
The number of drive objects specified in p10010 is not equal to the number of drives that have drive-based motion
monitoring functions that have been enabled.
The drive object number for drive n is set in p10010[n-1].
When this fault is present, none of the drives that have drive-based motion monitoring functions operating with
TM54F, are enabled.
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...