List of parameters
Parameters
1-1059
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
[3] = Drive group 4
Note:
Bit = 0 signal --> not selected
Bit = 1 signal --> selected
The selected signals (high-active) are OR'ed The result of the logic operation results in the status "Safe State".
Description:
Sets the input mode for the safety-relevant input terminals of terminal series 2.
Note:
Only an NC contact can be connected to terminals that are not listed in the selection.
Description:
Enable signal for the integration of F-DI in the test (forced checking procedure) of the sensor power supply.
Note:
F-DI: Failsafe Digital Input
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Power_removed
Selected
Not selected
-
01
SS1_active
Selected
Not selected
-
02
SS2_active
Selected
Not selected
-
03
SOS_active
Selected
Not selected
-
04
SLS_active
Selected
Not selected
-
p10040
SI F-DI input mode / SI F-DI inp_mode
TM54F_MA,
TM54F_SL
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
F-DI 0, DI 1+ (X521.3)
NO contact
NC contact
2850
01
F-DI 1, DI 3+ (X521.5)
NO contact
NC contact
2850
02
F-DI 2, DI 5+ (X522.2)
NO contact
NC contact
2850
03
F-DI 3, DI 7+ (X522.4)
NO contact
NC contact
2850
04
F-DI 4, DI 9+ (X522.6)
NO contact
NC contact
2850
05
F-DI 5, DI 11+ (X531.3)
NO contact
NC contact
2851
06
F-DI 6, DI 13+ (X531.5)
NO contact
NC contact
2851
07
F-DI 7, DI 15+ (X532.2)
NO contact
NC contact
2851
08
F-DI 8, DI 17+ (X532.4)
NO contact
NC contact
2851
09
F-DI 9, DI 19+ (X532.6)
NO contact
NC contact
2851
p10041
SI F-DI enable for test / SI F-DI enab test
TM54F_MA,
TM54F_SL
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2848
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
F-DI 0, power supply L1+
Test active
No test
-
01
F-DI 1, power supply L1+
Test active
No test
-
02
F-DI 2, power supply L1+
Test active
No test
-
03
F-DI 3, power supply L1+
Test active
No test
-
04
F-DI 4, power supply L1+
Test active
No test
-
05
F-DI 5, power supply L2+
Test active
No test
-
06
F-DI 6, power supply L2+
Test active
No test
-
07
F-DI 7, power supply L2+
Test active
No test
-
08
F-DI 8, power supply L2+
Test active
No test
-
09
F-DI 9, power supply L2+
Test active
No test
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...