Description:
Sets the number of measuring steps per revolution for a rotary absolute encoder. The resolution refers to the abso-
lute position.
Caution:
This parameter is automatically preset for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Description:
Sets the distance between two zero marks for a linear encoder. This information is used for zero mark monitoring.
Caution:
This parameter is automatically preset for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note:
For distance-coded zero marks, this means the basic distance.
Description:
Sets the distance in pulses between two zero marks for a rotary encoder. This information is used for zero mark
monitoring.
Caution:
This parameter is automatically preset for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note:
For distance-coded zero marks, this means the basic distance.
Description:
Sets the baud rate for an SSI encoder.
Caution:
This parameter is automatically preset for encoders from the encoder list (p0400). When selecting a catalog
encoder, this parameter cannot be changed (write protection). Information in p0400 should be carefully observed
when removing write protection.
Note:
SSI: Synchronous Serial Interface
p0423[0...n]
Absolute encoder rotary single-turn resolution / Enc abs singleturn
SERVO, VECTOR
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
EDS, p0140
Func. diagram:
4704
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 1073741823
8192
p0424[0...n]
Encoder, linear zero mark distance / Enc lin ZM_dist
SERVO, VECTOR
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 [mm]
65535 [mm]
20 [mm]
p0425[0...n]
Encoder, rotary zero mark distance / Enc rot dist ZM
SERVO, VECTOR
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
EDS, p0140
Func. diagram:
4704, 8570
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 16777215
2048
p0427[0...n]
Encoder SSI baud rate / Enc SSI baud rate
SERVO, VECTOR
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
EDS, p0140
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 [kHz]
65535 [kHz]
100 [kHz]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...