![Siemens SINAMICS S Series Скачать руководство пользователя страница 1024](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_12654271024.webp)
Parameters
List of parameters
1-1024
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Notice:
Re bit 07:
The signal state behaves in an opposite way to the PROFIsafe Standard.
Note:
Re bit 07:
An internal even is displayed if a STOP A ... F is active.
Description:
Displays the diagnostic signals for safety-relevant motion monitoring functions integrated in the drive.
Description:
Displays the crosswise comparison clock cycle (clock cycle time with which each individual DCC value is compared
between both monitoring channels.
Dependency:
Refer to: p9500
Note:
Crosswise comparison clock cycle = monitoring clock cycle (p9500) * number of data to be crosswise compared
DCC: Data cross-check
Description:
Displays the message value that resulted in the STOP F on the drive.
Value = 0 means:
The controlled signaled a STOP F.
Value = 1 ... 999 means:
Number of the incorrect crosswise compared data between the drive and control.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
STO active
Yes
No
-
01
SS1 active
Yes
No
-
02
SS2 active
Yes
No
-
03
SOS active
Yes
No
-
04
SLS active
Yes
No
-
07
Internal event
No
Yes
-
09
Active SLS stage bit 0
Set
Not set
-
10
Active SLS stage bit 1
Set
Not set
-
11
SOS selected
Yes
No
-
15
SSM (velocity below limit value)
Yes
No
-
r9723.0
CO/BO: SI Motion diagnostic signals integrated in the drive / SI Mtn integ diag
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Forced checking procedure required
Yes
No
-
r9724
SI Motion crosswise comparison clock cycle / SI Mtn DCC clk cyc
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]
r9725
SI motion, diagnostics STOP F / SI Mtn Diag STOP F
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...