![Siemens SINAMICS S Series Скачать руководство пользователя страница 170](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427170.webp)
Parameters
List of parameters
1-170
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
2112: 40000 nm, 1 Vpp, A/B R distance-coded
2151: 16000 nm, 1 Vpp, A/B, EnDat, resolution 100 nm
3001: 1024 HTL A/B R
3002: 1024 TTL A/B R
3003: 2048 HTL A/B R
3005: 1024 HTL A/B
3006: 1024 TTL A/B
3007: 2048 HTL A/B
3008: 2048 TTL A/B
3009: 1024 HTL A/B unipolar
3011: 2048 HTL A/B unipolar
3020: 2048 TTL A/B R, with sense
3081: SSI, Singleturn, 24 V
3082: SSI, Multiturn 4096, 24 V
3090: 4096, HTL, A/B, SSI, Singleturn
9999: User-defined
10000: Identify encoder
10050: Encoder with EnDat interface identified
Caution:
An encoder type with p0400 < 9999 defines an encoder for which there is an encoder parameter list. When select-
ing a catalog encoder (p0400 < 9999) the parameters from the encoder parameter list cannot be changed (write
protection). To remove write protection, the encoder type should be set to an unlisted encoder (p0400 = 9999).
Notice:
The list for motor codes /encoder codes can be found in the following literature:
SINAMICS S List Manual
Note:
The connected encoder can be identified by p0400 = 10000. This means that the encoder must support this and is
possible in the following cases: Motor with DRIVE-CLiQ, encoder with EnDat interface.
If an identification is not possible, then p0400 is set to 0.
The encoder data (e.g. pulse number p0408) can only be changed when p0400 = 9999.
When using an encoder with track A/B and zero pulse, as standard, fine synchronization is not set using the zero
mark. If, for a synchronous motor, the fine synchronization is to be realized using a zero mark, then the following
must be executed:
- set p0400 to 9999
- set p0404.15 to 1
Prerequisite:
Coarse synchronization must be selected (e.g. pole position identification) and the zero pulse of the encoder must
either be mechanically or electronically (p0431) adjusted to the pole position.
Description:
Selects the encoder from the list of encoder types that the OEM supports.
Note:
The connected encoder can be identified by p0400 = 10000. This means that the encoder must support this and is
possible in the following cases: Motor with DRIVE-CLiQ, encoder with EnDat interface.
If an identification is not possible, then p0400 is set to 0.
The encoder data (e.g. pulse number p0408) can only be changed when p0400 = 9999.
Using p0400 = 20000, the encoder type can be selected from the list of OEM encoders using p0401.
p0401[0...n]
Encoder type, OEM selection / Enc type OEM sel
SERVO, VECTOR
Can be changed:
C2(1, 4)
Calculated:
-
Access level:
2
Data type:
Integer16
Dynamic index:
EDS, p0140
Func. diagram:
1580, 4704
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 32767
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...