Parameters
List of parameters
1-74
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the torque/force generating current setpoint.
Note:
This value is irrelevant for the V/f control mode.
Description:
Displays the actual value for the active current.
Dependency:
Refer to: r0030
Note:
The active current actual value is available smoothed (r0030) and unsmoothed (r0078).
Description:
Displays the torque-generating current actual value (Iq_act).
Dependency:
Refer to: r0030
Note:
This value is irrelevant for the V/f control mode.
The torque-generating current actual value is available smoothed (r0030 with 300 ms) and unsmoothed (r0078).
Description:
Displays the torque-generating current actual value (Iq_act).
Index:
[0] = Unsmoothed
[1] = Smoothed with p0045
Dependency:
Refer to: r0030, p0045
Note:
These values are irrelevant for the V/f control mode.
The torque-generating current actual value is available smoothed (r0030 with 100 ms, r0078[1] with p0045) and
unsmoothed (r0078[0]).
r0077
CO: Current setpoint force-generating / Iq_set
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1630, 1774,
5714, 6710, 6714, 6719
P-Group:
Displays, signals
Units group:
6_2
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
r0078
CO: Active current actual value / Iq_act
A_INF, S_INF
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1774, 1775,
8850, 8946, 8950
P-Group:
Displays, signals
Units group:
6_2
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
r0078
CO: Current actual value, torque-generating / Iq_act
VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1710, 6310,
6714, 6799
P-Group:
Displays, signals
Units group:
6_2
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
r0078[0...1]
CO: Current actual value, torque-generating / Iq_act
SERVO
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1630, 5714,
5730
P-Group:
Displays, signals
Units group:
6_2
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...