![Siemens SINAMICS S Series Скачать руководство пользователя страница 65](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427065.webp)
List of parameters
Parameters
1-65
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency:
Refer to: r0020
Note:
The velocity setpoint is available smoothed (r0020) and unsmoothed (r0060).
Description:
Displays the speed sensed by the motor encoder (unsmoothed).
Description:
Displays the velocity sensed by the motor encoder (unsmoothed).
Description:
Displays the speed sensed by the motor encoder (unsmoothed).
Index:
[0] = Encoder 1
[1] = Encoder 2
Description:
Displays the actual speed setpoint after the setpoint filters.
r0061
CO: Speed actual value motor encoder / n_ist mot. encoder
SERVO
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1580, 4710,
4715
P-Group:
Displays, signals
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [RPM]
- [RPM]
- [RPM]
r0061
CO: Velocity actual value, motor encoder / v_act mot encoder
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1580, 4710,
4715
P-Group:
Displays, signals
Units group:
4_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [m/min]
- [m/min]
- [m/min]
r0061[0...1]
CO: Speed actual value motor encoder / n_ist mot. encoder
VECTOR
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1580, 4710,
4715
P-Group:
Displays, signals
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [RPM]
- [RPM]
- [RPM]
r0062
CO: Speed setpoint after the filter / n_set after filter
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
1590, 1750,
5020, 5030, 5210, 6030
P-Group:
Displays, signals
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [RPM]
- [RPM]
- [RPM]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...