![Siemens SINAMICS S Series Скачать руководство пользователя страница 1544](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_12654271544.webp)
Faults and Alarms
List of faults and alarms
3-1544
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
6. Direct encoder with position tracking for the measuring gearbox:
v = (p0412 * p2506) / p2576
Note:
With position tracking, it is recommended that p0412 and p2721 are changed
See also: p0412 (Measuring gearbox, rotary absolute gearbox, revolutions, virtual), p0432 (Gearbox factor, encoder
revolutions), p0433 (Gearbox factor, motor/load revolutions), p2504 (LR motor/load motor revolutions), p2505 (LR
motor/load motor revolutions), p2506 (LR length unit LU per load revolution), p2576 (EPOS modulo correction, mod-
ulo range), p2721 (Load gearbox, rotary absolute gearbox, revolutions, virtual)
Reaction upon A:
NONE
Acknowl. upon A:
NONE
F07443 (A)
LR: Reference point coordinate not in the permissible range
Drive object:
SERVO, VECTOR
Reaction:
OFF1 (OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
The reference point coordinate received when adjusting the encoder via connector input CI:p2599 lies outside the
half of the encoder range and cannot be set as actual axis position.
Fault value (r0949, interpret decimal):
Limit value (absolute value) for the reference point coordinate.
Remedy:
Set the reference point coordinate less than the limit value specified in the fault value.
See also: p2598 (EPOS reference point coordinate, signal source), p2599 (EPOS reference point coordinate value)
Reaction upon A:
NONE
Acknowl. upon A:
NONE
F07446 (A)
Load gearbox: Position tracking cannot be reset
Drive object:
SERVO, VECTOR
Reaction:
OFF1 (OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
The position tracking cannot be reset.
Remedy:
Reaction upon A:
NONE
Acknowl. upon A:
NONE
F07447
Load gearbox: Position tracking, maximum actual value exceeded
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
When the position tracking of the load gearbox is configured, the drive/encoder (motor encoder) identifies a maxi-
mum possible absolute position actual value (r2723) that can no longer be represented within 32 bits.
Maximum value: p0408 * p2721 * 2^p0419
See also: p0408 (Rotary encoder pulse No.), p0419 (Fine resolution absolute value Gx_XIST2 (in bits)), p2721
(Load gearbox, rotary absolute gearbox, revolutions, virtual)
Remedy:
- reduce the fine resolution (p0419).
- reduce the multiturn resolution (p2721).
See also: p0419 (Fine resolution absolute value Gx_XIST2 (in bits)), p2721 (Load gearbox, rotary absolute gearbox,
revolutions, virtual)
F07448 (A)
Load gearbox: Position tracking, linear axis has exceeded the maximum range
Drive object:
SERVO, VECTOR
Reaction:
OFF1 (NONE, OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
For a configured linear axis/no modulo axis, the drive/encoder has exceeded the maximum possible traversing
range.
For the configured linear axis, the maximum traversing range is defined to be 64x (+/- 32x) of p0421. It should be
read in p2721 and interpreted as the number of load revolutions.
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...