List of parameters
Parameters
1-167
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the rated current (I_F) for the excitation.
Description:
Sets the starting point of the current-dependent current controller adaptation where the current controller gain
p1715 is effective.
Dependency:
Refer to: p0392, p0393, p1402, p1715
Caution:
This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Note:
For p0393 = 100 % or p1402 bit 2 = 0, the current controller adaptation is disabled and p1715 is effective over the
entire range.
Description:
Sets the starting point of the current-dependent current controller adaptation where the current controller gain
p1715 is effective.
Dependency:
Refer to: p0392, p0393, p1402, p1715
Caution:
This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
Description:
Sets the starting point of the current-dependent current controller adaptation where the adapted current controller
gain p1715 * p0393 is effective.
Dependency:
Refer to: p0391, p0393, p1402, p1715
Caution:
This parameter is automatically preset for motors from the motor list (p0301). When selecting a catalog motor, this
parameter cannot be changed (write protection). Information in p0300 should be carefully observed when removing
write protection.
p0390[0...n]
Rated excitation current / Exc I_rated
VECTOR
Can be changed:
C2(1, 3)
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
6727
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
ASM, PEM, REL
Expert list:
1
Min Max
Factory
setting
0.00 [A]
10000.00 [A]
0.00 [A]
p0391[0...n]
Current controller adaptation, starting point KP / I_adapt pt KP
SERVO
Can be changed:
C2(3), U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
5714
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [Arms]
6000.00 [Arms]
0.00 [Arms]
p0391[0...n]
Current controller adaptation, starting point KP / I_adapt pt KP
VECTOR
Can be changed:
C2(3), U, T
Calculated:
CALC_MOD_REG
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
6714
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [Arms]
6000.00 [Arms]
0.00 [Arms]
p0392[0...n]
Current controller adaptation, starting point KP adapted / I_adapt pt KP adap
SERVO
Can be changed:
C2(3), U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
5714
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.00 [Arms]
6000.00 [Arms]
0.00 [Arms]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...