![Siemens SINAMICS S Series Скачать руководство пользователя страница 165](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427165.webp)
List of parameters
Parameters
1-165
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the damping inductance of the separately-excited synchronous motor in the rotor direction (d-axis).
Description:
Displays the damping inductance of a separately-excited synchronous motor quadrature to the rotor direction (q
axis).
Description:
Displays the magnetizing inductance of the motor.
For separately-excited synchronous motors: Displays the saturated magnetizing inductance in the rotor direction (d-
axis).
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
Description:
Displays the saturated magnetizing inductance of a separately-excited synchronous motor quadrature to the rotor
direction (q axis).
Description:
Displays the rotor time constant.
For separately-excited synchronous motors: Displays the damping time constant in the rotor direction (d-axis).
r0380[0...n]
Motor damping inductance, d axis / Mot L_damping_d
VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
15_1
Unit selection:
p0349
Not for motor type:
ASM, PEM, REL
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
r0381[0...n]
Motor damping inductance, q axis / Mot L_damping_q
VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
15_1
Unit selection:
p0349
Not for motor type:
ASM, PEM, REL
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
r0382[0...n]
Motor magnetizing inductance transformed / Lh d axis saturated / Mot L_m tr/Lhd sat
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
15_1
Unit selection:
p0349
Not for motor type:
PEM, REL
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
r0383[0...n]
Motor magnetizing inductance q axis, saturated / Mot L_magn q sat
VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
15_1
Unit selection:
p0349
Not for motor type:
ASM, PEM, REL
Expert list:
1
Min Max
Factory
setting
- [mH]
- [mH]
- [mH]
r0384[0...n]
Motor rotor time constant / damping time constant d axis / Mot T_rotor/T_Dd
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
6722
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL
Expert list:
1
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...