Parameters
List of parameters
1-430
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the signal source for the lower torque limit.
Dependency:
Refer to: p1520, p1521, p1522
Danger:
Positive values. that are obtained as a result of the signal source and the scaling can cause the motor to accelerate
in an uncontrollable fashion.
Description:
Sets the scaling for the upper torque limit or the torque limit when motoring.
Dependency:
p1400 bit 4 = 0: Upper / lower
p1400 bit 4 = 1: Motoring / generating
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Note:
This parameter can be freely interconnected.
The value has the above significance if it is interconnected from connector input p1528.
Description:
Sets the scaling for the upper force limit or the force limit when motoring.
Dependency:
p1400 bit 4 = 0: Upper / lower
p1400 bit 4 = 1: Motoring / generating
Notice:
A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Note:
This parameter can be freely interconnected.
The value has the above significance if it is interconnected from connector input p1528.
p1523[0...n]
CI: Torque limit lower / M_max lower
VECTOR (n/M)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
6630
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
- -
1521[0]
p1524[0...n]
CO: Torque limit upper/motoring scaling / M_max up/mot scal
SERVO
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5620, 5630,
6630
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
-2000.0 [%]
2000.0 [%]
100.0 [%]
p1524[0...n]
CO: Force limit upper/motoring scaling / F_max up/mot scal
SERVO (Lin)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
5620, 5630,
6630
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
-2000.0 [%]
2000.0 [%]
100.0 [%]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...