Parameters
List of parameters
1-244
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
This feedback signal (0/1 edge) is required after a motor changeover to enable the pulses.
Dependency:
Refer to: p0833
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description:
Displays the status word of the motor changeover.
These signals can be connected to digital outputs to change over the motor.
Dependency:
Refer to: p0827
Description:
Sets the signal source for the feedback signal of the contactors when changing over motors.
There is a fixed inter-relationship between energizing the contactor and the feedback signal.
Example:
A changeover is to be made between MDS0 (motor 0) and MDS1 (motor 1). The contactors should be switched
using bit 4 (contactor 0) and 5 (contactor 1). The changeover should be made with an interconnection of the feed-
back signal.
Implementation:
MDS0: p0827[0] = 4, interconnect output to switch contactor 0 to r0830.4, p0831[4] = "input, feedback signal, con-
tactor 0"
MDS1: p0827[1] = 5, interconnect output to switch contactor 1 to r0830.5, p0831[5] = "input, feedback signal, con-
tactor 1"
The following sequence applies when changing over from MDS0 to MDS1:
1. The status bit p0830.4 is deleted. When the feedback signal (p0831[4]) is connected, the system waits until the
feedback signal "contactor open" is displayed. If the feedback signal is not connected, then the system waits for the
switch-off interlocking time of 320 ms.
r0830.0...15
CO/BO: Motor changeover, status word / Mot_chngov ZSW
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
8575
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Motor selection, bit 0
High
Low
-
01
Motor selection, bit 1
High
Low
-
02
Motor selection, bit 2
High
Low
-
03
Motor selection, bit 3
High
Low
-
04
Motor selection, bit 4
High
Low
-
05
Motor selection, bit 5
High
Low
-
06
Motor selection, bit 6
High
Low
-
07
Motor selection, bit 7
High
Low
-
08
Motor selection, bit 8
High
Low
-
09
Motor selection, bit 9
High
Low
-
10
Motor selection, bit 10
High
Low
-
11
Motor selection, bit 11
High
Low
-
12
Motor selection, bit 12
High
Low
-
13
Motor selection, bit 13
High
Low
-
14
Motor selection, bit 14
High
Low
-
15
Motor selection, bit 15
High
Low
-
p0831[0...15]
BI: Motor changeover, contactor feedback / Mot_chg cont fdbk
SERVO, VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
8575
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...