List of parameters
Parameters
1-991
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the number of signal sources from this drive to other drives/drive objects (Binector Output/Connector Out-
put, BO/CO).
Dependency:
Refer to: r9491, r9492, p9493
Description:
Displays the signal receiver list (Binector Input/Connector Input, BI/CI) for the first interconnections between this
drive and other drives/drive objects.
Dependency:
Refer to: r9490, r9492, p9493
Notice:
A drive cannot be deleted if this list is not empty! Otherwise, another drive would continue to attempt to read a sig-
nal from a drive that no longer existed.
Note:
All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
Description:
Displays the signal source list (Binector Output/Connector Output, BO/CO) for the first interconnections between
this drive and other drives/drive objects.
Dependency:
Refer to: r9490, r9491, p9493
Notice:
A drive cannot be deleted if this list is not empty! Otherwise, another drive would continue to attempt to read a sig-
nal from a drive that no longer existed.
Note:
All indices of r9491 to p9493 designate the same interconnection.
r9491[x] contains the signal receiver and r9492[x] the matching signal source; p9493[x] can be set to modify the
interconnection.
Description:
Setting to reset the BICO interconnections to other drives. Each interconnection can be individually reset.
r9490
Number of BICO interconnections to other drives / Qty BICO to drive
All objects
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r9491[0...9]
BI/CI of BICO interconnections to other drives / BI/CI to drive
All objects
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r9492[0...9]
BO/CO of BICO interconnections to other drives / BO/CO to drive
All objects
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p9493[0...9]
Reset BICO interconnections to other drives / Reset BICO to drv
All objects
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 15
15
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...