Parameters
List of parameters
1-256
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
In order that signal BO: r0873 is available at one of the infeeds, then BI: p0874 of the one infeed must be intercon-
nected to BO: r0863.0 of the other infeed.
Dependency:
Refer to: r0863, p0874
Note:
Mixed operation is not possible with the Active Line Module (ALM)!
Description:
Setting to interconnect the ready signal for mixed operation of Smart Line Module (SLM) and Basic Line Module
(BLM).
In order that signal BO: r0873 is available at one of the infeeds, then BI: p0874 of the one infeed must be intercon-
nected to BO: r0863.0 of the other infeed.
Dependency:
Refer to: r0863, r0873
Note:
Mixed operation is not possible with the Active Line Module (ALM)!
Description:
Sets the signal source to activate/de-activate a power unit component.
Dependency:
BI: p0895 = 0 signal
De-activating power unit components
BI: p0895 = 1 signal
Activating power unit components
Refer to: p0125, r0126
Refer to: A05054
Note:
The power unit is only de-activated when the pulses are canceled.
For units connected in parallel, when one of the power units is deactivated, then the enable in p7001 is withdrawn.
Description:
Displays the status word for the "parking axis" function.
Dependency:
Refer to: p0897
p0874
BI: Smart/ Basic Line Module operation / SLM/BLM operation
B_INF, S_INF
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
8732, 8832
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p0895[0...n]
BI: Activate/de-activate power unit components / PU_comp act/de-act
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
1
r0896.0
BO: Parking axis, status word / Parking axis, ZSW
SERVO, VECTOR
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned8
Dynamic index:
-
Func. diagram:
-
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Parking axis active
Yes
No
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...