![Siemens SINAMICS S Series Скачать руководство пользователя страница 314](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427314.webp)
Parameters
List of parameters
1-314
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the effective negative velocity limit.
Dependency:
Refer to: p1082, p1086, p1088
Description:
Sets the signal source for the speed/velocity limit of the negative direction.
Description:
Sets the signal source for the speed/velocity limit of the negative direction.
Description:
Sets skip speed 1.
Dependency:
Refer to: p1092, p1093, p1094, p1101
Note:
The skip (suppression) speeds can be used to prevent the effects of mechanical resonance.
Description:
Sets skip velocity 1.
Dependency:
Refer to: p1092, p1093, p1094, p1101
Note:
The skip (suppression) velocities can be used to prevent the effects of mechanical resonance.
r1087
Velocity limit negative effective / v_limit neg eff
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
3050, 5030,
5210, 6640, 7020, 8010
P-Group:
Setpoints
Units group:
4_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [m/min]
- [m/min]
- [m/min]
p1088[0...n]
CI: Speed limit negative direction of rotation / n_limit neg
SERVO (Extended
setp), VECTOR
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
3050
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
1086[0]
p1088[0...n]
CI: Velocity limit negative direction / n_limit neg
SERVO (Extended
setp, Lin)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
3050
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
1086[0]
p1091[0...n]
Skip speed 1 / n_skip 1
SERVO (Extended
setp), VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
3050
P-Group:
Setpoints
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [RPM]
210000.000 [RPM]
0.000 [RPM]
p1091[0...n]
Skip velocity 1 / v_skip 1
SERVO (Extended
setp, Lin)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
3050
P-Group:
Setpoints
Units group:
4_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [m/min]
1000.000 [m/min]
0.000 [m/min]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...