![Siemens SINAMICS S Series Скачать руководство пользователя страница 647](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427647.webp)
List of parameters
Parameters
1-647
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency:
Refer to: p2578, p2580, p2581, p2582
Refer to: A07470, A07478, A07480, F07482
Notice:
A change to the software limit switch becomes immediately effective.
If the software limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note:
The following applies for the setting of the software limit switch:
Software limit switch minus < software limit switch plus
Description:
Sets the software limit switch in the negative direction of travel.
Dependency:
Refer to: p2578, p2579, p2581, p2582
Description:
Sets the software limit switch in the positive direction of travel.
Dependency:
Refer to: p2578, p2579, p2580, p2582
Description:
Sets the signal source to activate the "software limit switch".
Dependency:
Refer to: p2578, p2579, p2580, p2581
Caution:
Software limit switch effective:
- axis is referenced (r2684.11 = 1) and BI: p2582 = 1 signal.
Software limit switch ineffective:
- modulo correction active (BI: p2577 = 1 signal).
- search for reference is executed.
Notice:
Target position for relative positioning outside software limit switch:
The traversing block is started and the axis comes to a standstill at the software limit switch. An appropriate alarm is
output and the traversing block is interrupted. Traversing blocks with valid position can be activated.
Target position for absolute positioning outside software limit switch:
In the "traversing blocks" mode, the traversing block is not started and an appropriate fault is output.
Axis outside the valid traversing range:
If the axis is already outside the valid traversing range, then an appropriate fault is output. The fault can be acknowl-
edged at standstill. Traversing blocks with valid position can be activated.
Note:
The traversing range can also be limited using STOP cams.
p2580
CO: EPOS software limit switch minus / SW limSwitch minus
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
-
Func. diagram:
3630
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-2147482648 [LU]
2147482647 [LU]
-2147482648 [LU]
p2581
CO: EPOS software limit switch plus / SW lim switch plus
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
-
Func. diagram:
3630
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-2147482648 [LU]
2147482647 [LU]
2147482647 [LU]
p2582
BI: EPOS software limit switch activation / SW lim sw act
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
3630
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...