![Siemens SINAMICS S Series Скачать руководство пользователя страница 794](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427794.webp)
Parameters
List of parameters
1-794
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
DI/DO: Bidirectional Digital Input/Output
Description:
Displays the actual input voltage at the analog inputs of the Terminal Board 30 (TB30).
Index:
[0] = AI 0 (X482.1/X482.2)
[1] = AI 1 (X482.3/X482.4)
Note:
AI: Analog Input
Description:
Displays the actual input voltage in V when set as voltage input.
Displays the actual input current in mA when set as current input and with the load resistor switched-in.
Index:
[0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
Dependency:
The type of analog input AI x (voltage or current input) is set using p4056.
Refer to: r4056, p4056
Note:
AI: Analog Input
Description:
Displays the actual input voltage in V.
07
DI/DO 7 (X520.9)
I/O with time
I/O
-
08
DI/DO 8 (X521.2)
I/O with time
I/O
-
09
DI/DO 9 (X521.3)
I/O with time
I/O
-
10
DI/DO 10 (X522.4)
I/O with time
I/O
-
11
DI/DO 11 (X521.5)
I/O with time
I/O
-
12
DI/DO 12 (X521.6)
I/O with time
I/O
-
13
DI/DO 13 (X521.7)
I/O with time
I/O
-
14
DI/DO 14 (X521.8)
I/O with time
I/O
-
15
DI/DO 15 (X521.9)
I/O with time
I/O
-
16
DI/DO 16 (X522.2)
I/O with time
I/O
-
17
DI/DO 17 (X522.3)
I/O with time
I/O
-
18
DI/DO 18 (X522.4)
I/O with time
I/O
-
19
DI/DO 19 (X522.5)
I/O with time
I/O
-
20
DI/DO 20 (X522.6)
I/O with time
I/O
-
21
DI/DO 21 (X522.7)
I/O with time
I/O
-
22
DI/DO 22 (X522.8)
I/O with time
I/O
-
23
DI/DO 23 (X522.9)
I/O with time
I/O
-
r4052[0...1]
CO: TB30 analog inputs, actual input voltage / TB30 AI inp_V
TB30
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
9104
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [V]
- [V]
- [V]
r4052[0...1]
CO: TM31 analog inputs, actual input voltage/current / TM31 AI inp_V/I
TM31
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
9566, 9568
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
r4052[0...0]
CO: TB41 analog inputs, actual input voltage / TM41 AI inp_V
TM41
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
9663
P-Group:
Terminals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [V]
- [V]
- [V]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...