![Siemens SINAMICS S Series Скачать руководство пользователя страница 664](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427664.webp)
Parameters
List of parameters
1-664
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
This signal is only effective in the modes "traversing blocks" and "direct setpoint input/MDI".
When activating reject traversing tasks, then the axis brakes with the maximum deceleration (p2573).
Description:
Sets the signal source for the position setpoint in the mode "direct setpoint input/MDI".
Dependency:
Refer to: p2648, p2649, p2650, p2690
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Depending on p2649, the position setpoint is either transferred continuously or edge-triggered.
The position setpoint input is interpreted as length unit [LU].
Description:
Sets the signal source for the velocity setpoint in the "direct setpoint input/MDI mode".
Dependency:
Refer to: p2649, p2650, p2691
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Depending on p2649, the velocity setpoint is either transferred continuously or edge-triggered.
The velocity setpoint input is interpreted as [1000 LU/min].
Description:
Sets the signal source for the acceleration override in the operating mode "direct setpoint input/MDI".
Dependency:
Refer to: p2649, p2650, p2692
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Depending on p2649, the acceleration override is either transferred continuously or edge-triggered.
The signal value 4000 hex (16384 dec) corresponds to 100 %.
Description:
Sets the signal source for the deceleration override in the operating mode "direct setpoint input/MDI".
Dependency:
Refer to: p2649, p2650, p2693
p2642
CI: EPOS direct setpoint input/MDI position setpoint / MDI s_set
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Integer32
Dynamic index:
-
Func. diagram:
3618
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
2690[0]
p2643
CI: EPOS direct setpoint input/MDI velocity setpoint / MDI v_set
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Integer32
Dynamic index:
-
Func. diagram:
3618
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
2691[0]
p2644
CI: EPOS direct setpoint input/MDI acceleration override / MDI a_over
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
-
Func. diagram:
3618
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
2692[0]
p2645
CI: EPOS direct setpoint input/MDI deceleration override / MDI -a_over
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
-
Func. diagram:
3618
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
2693[0]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...