![Siemens SINAMICS S Series Скачать руководство пользователя страница 239](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427239.webp)
List of parameters
Parameters
1-239
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
This parameter is not saved when data is backed-up (p0971, p0977).
Description:
Sets the setpoint for the input signals in the digital input simulation mode.
Description:
Sets the sampling time for the inputs and outputs.
Dependency:
The parameter can only be modified for p0009 = 3, 29.
The sampling times can only be set as an integer multiple of the basic sampling time (p0110, p0111).
Refer to: p0009, r0110, r0111
Note:
The modified sampling time is not effective until the drive unit is powered-up again.
Description:
Sets the sampling time for the inputs and outputs.
p0796
CX digital inputs, simulation mode, setpoint / CX DI simul setp
CU_CX32
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2020, 2030,
2031
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DI 0 (X122.1)
High
Low
-
01
DI 1 (X122.2)
High
Low
-
02
DI 2 (X122.3)
High
Low
-
03
DI 3 (X122.4)
High
Low
-
08
DI/DO 8 (X122.7)
High
Low
-
09
DI/DO 9 (X122.8)
High
Low
-
10
DI/DO 10 (X122.10)
High
Low
-
11
DI/DO 11 (X122.11)
High
Low
-
p0799
CU inputs/outputs, sampling time / CU I/O t_sampl
CU_S
Can be changed:
C1(3)
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
2020, 2030,
2031, 2120, 2121, 2130, 2131,
2132, 2133
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [µs]
5000.00 [µs]
4000.00 [µs]
p0799
CX inputs/outputs, sampling time / CX I/O t_sampl
CU_CX32
Can be changed:
C1(3)
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
2220, 2230,
2231
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [µs]
5000.00 [µs]
4000.00 [µs]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...