Parameters
List of parameters
1-320
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
The ramp-function generator ramps-down the speed setpoint from the maximum speed (p1082) down to standstill
(setpoint = 0) in this time. Further, the ramp-down time is always effective for OFF1.
Dependency:
Refer to: p1082
Note:
The following applies for SERVO:
The ramp-function generator is only available when the function module "expanded setpoint channel" is active
(r0108.8 = 1).
Description:
The drive is decelerated from the maximum velocity (p1082) down to standstill (setpoint = 0) in this time.
Dependency:
Refer to: p1082
Note:
The following applies for SERVO:
The ramp-function generator is only available when the function module "expanded setpoint channel" is active
(r0108.8 = 1).
Description:
Sets the signal source for bypassing the ramp generator (ramp-up and ramp-down times = 0).
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
For VECTOR in sensorless operation, it is not permissible that the ramp-function generator is bypassed.
Description:
Sets the initial rounding-off time for the extended ramp generator. The value applies to ramp-up and ramp-down.
Note:
Rounding-off times avoid an abrupt response and prevent damage to the mechanical system.
p1121[0...n]
Ramp-function generator ramp-down time / RFG ramp-down time
SERVO, VECTOR
Can be changed:
C2(1), U, T
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
3060, 3070
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [s]
999999.000 [s]
10.000 [s]
p1121[0...n]
Ramp-function generator ramp-down time / RFG ramp-down time
SERVO (Lin)
Can be changed:
C2(1), U, T
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
3060, 3070
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [s]
999999.000 [s]
0.000 [s]
p1122[0...n]
BI: Bypass ramp-function generator / Bypass RFG
SERVO (Extended
setp), VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
2505
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p1130[0...n]
Ramp-function generator initial rounding-off time / RFG t_start_round
SERVO (Extended
setp), VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
3070
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.000 [s]
30.000 [s]
0.000 [s]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...