![Siemens SINAMICS S Series Скачать руководство пользователя страница 712](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427712.webp)
Parameters
List of parameters
1-712
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets a steady-state supplementary setpoint for the active line supply current.
Dependency:
Refer to: p3515
Description:
Sets the signal source for the supplementary setpoint of the active current.
Dependency:
Refer to: p3514
Note:
For a master-slave infeed, the master can enter the current setpoint via this connector input.
Description:
Sets the factor to be multiplied by the active current setpoint for the current controller.
For a master slave infeed configuration, the value reduced in this way can be distributed to the slave axes. The
overall gain from the perspective of the voltage controller remains the same.
Description:
Displays the unlimited setpoint of the active current controller.
For a master-slave infeed configuration, the master retrieves this setpoint and distributes it to all of the slaves. The
slaves operate in the current-controlled mode.
p3514
Infeed supplementary active current steady-state / INF I_sup_eff stat
A_INF
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
8940
P-Group:
Closed-loop control
Units group:
6_2
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-1000.00 [Arms]
1000.00 [Arms]
0.00 [Arms]
p3515
CI: Infeed supplementary active current / INF I_suppl eff
A_INF
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
-
Func. diagram:
8940
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p3516
Infeed current distribution factor (parallel connection) / INF I_distr_factor
A_INF
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
8940, 8942
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [%]
100.00 [%]
100.00 [%]
r3517
CO: Infeed active current controller unlimited setpoint / INF I_act ctrl set
A_INF
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
8940
P-Group:
Closed-loop control
Units group:
6_2
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [Arms]
- [Arms]
- [Arms]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...