Description:
Sets the signal source for the reversing cam in the negative direction of travel.
1 signal: Reversing cam not reached.
0 signal: Reversing cam reached.
Dependency:
Refer to: p2613
Note:
If, during the search for reference from the reversing cam minus and plus, a 0 signal is detected, then the axis
remains stationary (at standstill).
Description:
Sets the maximum number of traversing blocks that are available.
Dependency:
Refer to: p2616, p2617, p2618, p2619, p2620, p2621, p2622, p2623, p2624
Description:
Sets a block number.
-1: Invalid block number. These blocks are not taken into account.
0 ... 63: Valid block number.
Dependency:
The number of indices depends on p2615.
Refer to: p2615, p2617, p2618, p2619, p2620, p2621, p2622, p2623, p2624
Description:
Sets the target position for the traversing block.
Dependency:
The number of indices depends on p2615.
Refer to: p2615, p2616, p2618, p2619, p2620, p2621, p2622, p2623, p2624
Note:
The target position is approached in either relative or absolute terms depending on p2623.
p2614
BI: EPOS search for reference reversing cam plus / Rev plus
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
3612
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
1
p2615
EPOS maximum number of traversing blocks / Trav_block qty max
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
C2(17)
Calculated:
-
Access level:
1
Data type:
Unsigned8
Dynamic index:
-
Func. diagram:
3616
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
1 64
64
p2616[0...n]
EPOS traversing block, block number / Trav_blk, blkNo.
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
p2615
Func. diagram:
3616
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-1 63
-1
p2617[0...n]
EPOS traversing block position / Trav_block pos
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
p2615
Func. diagram:
3616
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-2147482648 [LU]
2147482647 [LU]
0 [LU]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...