![Siemens SINAMICS S Series Скачать руководство пользователя страница 781](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427781.webp)
List of parameters
Parameters
1-781
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
DI/DO: Bidirectional Digital Input/Output
Description:
Sets the signal source for digital output DO 0 (X481.5) of the Terminal Board 30 (TB30).
Note:
DO: Digital Output
Description:
Sets the signal source for the digital output DO 0 (X542.1, X542.2, X542.3) of terminal module 31 (TM31).
Digital output 0 of TM31 is a relay output.
If the signal at the binector input p4030 is low, then terminal COM 0 (X542.2) is connected to NC 0 (X542.1). This
connection also matches the mechanical quiescent setting of the relay.
If the signal at the binector input p4030 is high, then terminal COM 0 (X542.2) is connected to NO 0 (X542.3).
Note:
DO: Digital Output
NC: Normally Closed contact
NO: Normally Open contact
Description:
Sets the signal source for terminal DI/DO 0 (X520.2) of terminal module 15 (TM15).
Note:
Prerequisite: The DI/DO must be set as an output (p4028.0 = 1).
DI/DO: Bidirectional Digital Input/Output
Description:
Sets the signal source for terminal DO 1 (X481.6) of the Terminal Board 30 (TB30).
Note:
DO: Digital Output
21
DI/DO 21 (X522.7)
Output
Input
-
22
DI/DO 22 (X522.8)
Output
Input
-
23
DI/DO 23 (X522.9)
Output
Input
-
p4030
BI: TB30 signal source for terminal DO 0 / TB30 S_src DO 0
TB30
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
1790, 9102
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p4030
BI: TM31 signal source for terminal DO 0 / TM31 S_src DO 0
TM31
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
1840, 9556
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p4030
BI: TM15DI/DO signal source for terminal DI/DO 0 / TM15D S_srcDI/DO 0
TM15DI_DO
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
9400
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p4031
BI: TB30 signal source for terminal DO 1 / TB30 S_src DO 1
TB30
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
9102
P-Group:
Commands
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...