![Siemens SINAMICS S Series Скачать руководство пользователя страница 219](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427219.webp)
List of parameters
Parameters
1-219
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the constant kT7 for the torque characteristic:
kT(iq)=kT1+kT3*iq^2+kT5*iq^4+kT7*iq^6
Dependency:
Refer to: p0645, p0646, p0647
Description:
Displays the operating hours for the corresponding motor.
The motor operating time counter continues to run when the pulses are enabled. When the pulse enable is with-
drawn, the counter is held and the value saved.
Dependency:
The following prerequisites must be fulfilled in order to be able to save the operating hours counter in a non-volatile
fashion:
- firmware with V2.2 or higher.
- Control Unit 320 (CU320) with hardware version C or higher (module with NVRAM).
Refer to: p0651
Refer to: A01590
Note:
The operating hours counter in p0650 can only be reset to 0. In this case, p0651 is automatically set to 0.
For p0651 = 0, the operating hours counter is disabled.
The operating hours counter only runs for MDS0 and MDS1 (Motor Data Set).
Description:
Sets the service/maintenance intervals in hours for the appropriate motor.
An appropriate fault is output when the operating hourse set here are reached.
Dependency:
Refer to: p0650
Refer to: A01590
Note:
For p0651 = 0, the operating hours counter is disabled.
The operating hours counter only runs for MDS0 and MDS1 (Motor Data Set).
p0648[0...n]
Motor-torque characteristic kT7 / Mot kT7
SERVO (Exp M_ctrl)
Can be changed:
C2(1, 3), U, T
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
ASM, REL, FEM
Expert list:
1
Min Max
Factory
setting
- -
-
p0650[0...n]
Actual motor operating hours / Mot t_oper act
SERVO, VECTOR
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 [h]
4294967295 [h]
0 [h]
p0651[0...n]
Motor operating hours maintenance interval / Mot t_op maint
SERVO, VECTOR
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 [h]
99999 [h]
0 [h]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...