Parameters
List of parameters
1-380
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
Re bit 07:
The interpolator is only effective for clock-cycle synchronous PROFIBUS operation and when the master receives a
sign of life (STW 2.12 ... STW 2.15). Further, for active Dynamic Servo Control (DSC) an additional dead time of
one velocity controller clock cycle is obtained.
Re bit 11:
If the motor rotates when the pulses are enabled, then we recommend p1400.11 = 1 (starting value = setpoint) with
the matching sign.
If the motor remains stationary (zero speed) when the pulses are enabled, the we recommend p1400.11 = 0 (start-
ing value = 0.0).
Re bit 12:
If a changeover is made from operation with encoder to sensorless (without encoder) operation while accelerating
(with the threshold from p1404), then we recommend p1400.12 = 0.
If the changeover is made from operation with encoder to sensorless (without encoder) at constant speed/velocity
(e.g. with a DDS changeover or if there is an encoder fault via p0491) then we recommend p1400.12 = 1.
Description:
Sets the configuration for the closed-loop speed control.
Note:
Re bit 01:
When the bit is set, the I component of the speed controller is kept when changing into the open-loop controlled
mode.
Description:
Sets the configuration for flux setpoint control
09
Damping for sensorless open-loop con-
trolled oper.
Yes
No
-
10
Velocity pre-control
For balancing
For setp_filter 2
-
11
Sensorless oper. velocity actual value start-
ing value
Setpoint
0.0
-
12
Sensorless operation changeover
Steady-state
When accelerating
-
13
Motoring/regenerating depending on
Speed setpoint
Actual speed value
-
p1400[0...n]
Speed control configuration / n_ctrl config
VECTOR (n/M)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
DDS, p0180
Func. diagram:
6490
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
-
-
1000 0000 0010 0001 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Automatic Kp/Tn adaptation active
Yes
No
-
01
Sensorless vector control freeze I comp
Yes
No
-
02
Acceleration pre-control source
External (p1495)
Internal (n_set)
6031
03
Reference model speed setpoint, I compo-
nent
On
Off
6031
05
Kp/Tn adaptation active
Yes
No
-
06
Free Tn adaptation active
Yes
No
-
14
Torque pre-control
Always active
For n_ctrl enab
-
15
Sensorless vector control, speed pre-control Yes
No
-
p1401[0...n]
Flux control configuration / F_ctrl config
VECTOR (n/M)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
DDS, p0180
Func. diagram:
6491, 6722
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
PEM, REL
Expert list:
1
Min Max
Factory
setting
- -
1110
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Flux setpoint soft starting active
Yes
No
-
01
Flux setpoint differentiation active
Yes
No
-
02
Flux build-up control active
Yes
No
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...