![Siemens SINAMICS S Series Скачать руководство пользователя страница 54](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427054.webp)
Parameters
List of parameters
1-54
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency:
Refer to: p0290, p0294
Refer to: F30005
Description:
Displays the Control Unit temperature.
An appropriate signal is output when 85°C is exceeded.
Index:
[0] = Control Unit temperature actual
[1] = Control Unit temperature maximum
Dependency:
Refer to: A01009
Note:
The value of -200 indicates that there is no measuring signal.
Re r0037[0]:
Displays the currently measured Control Unit temperature.
Re r0037[1]:
Displays the highest measured Control Unit temperature. This value is saved on the module in a non-volatile fash-
ion.
Description:
Displays the temperatures in the power unit.
Index:
[0] = Maximum inverter
[1] = Maximum depletion layer
[2] = Maximum rectifier
[3] = Air intake
[4] = Electronics unit in the power unit
[5] = Inverter 1
[6] = Inverter 2
[7] = Inverter 3
[8] = Inverter 4
[9] = Inverter 5
[10] = Inverter 6
[11] = Rectifier 1
[12] = Rectifier 2
[13] = Depletion layer 1
[14] = Depletion layer 2
[15] = Depletion layer 3
[16] = Depletion layer 4
[17] = Depletion layer 5
[18] = Depletion layer 6
[19] = Cooling system, liquid intake
Note:
The value of -200 indicates that there is no measuring signal.
r0037[0]: Maximum value of the inverter temperatures (r0037[5...10]).
r0037[1]: Maximum value of the depletion layer temperatures (r0037[13...18]).
r0037[2]: Maximum value of the rectifier temperatures (r0037[11...12]).
r0037[0...1]
Control Unit temperature / CU temperature
CU_CX32, CU_S
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Displays, signals
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
r0037[0...19]
CO: Power unit temperatures / PU temperatures
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
8014
P-Group:
Displays, signals
Units group:
21_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [°C]
- [°C]
- [°C]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...