Parameters
List of parameters
1-186
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency:
Refer to: p0600, p0601
Note:
A value of zero is displayed if an encoder is not present.
Description:
Sets the Sensor Module configuration.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: p0600, p0601
07
Hall sensor can be combined with actual
value inversion
Yes
No
-
08
External temperature evaluation being used Yes
No
-
09
Encoder fault and its associated information
available
Yes
No
-
10
Speed diagnostics in the Sensor Module
Yes
No
-
11
-
16
Pole position identification
Yes
No
-
17
Burst oversampling
Yes
No
-
19
Safety position actual value sensing
Yes
No
-
20
Extended speed calculation being used
(only SMC30)
Yes
No
-
21
Zero mark tol
Yes
No
-
22
Rot pos adapt
Yes
No
-
27
SSI position value extrapolation
Yes
No
-
29
Phase correction
Yes
No
-
30
Amplitude correction
Yes
No
-
31
Offset correction
Yes
No
-
r0458[0...2]
Sensor Module properties / SM properties
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
4704
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Encoder data available
Yes
No
-
01
Motor data available
Yes
No
-
02
KTY84 connection available
Yes
No
-
03
PTC connection available
Yes
No
-
04
Module temperature available
Yes
No
-
05
Absolute encoder p0408/p0421, no power
of 2
Yes
No
-
06
Sensor Module permits parking/unparking
Yes
No
-
07
Hall sensor can be combined with actual
value inversion
Yes
No
-
08
External temperature evaluation being used Yes
No
-
09
Encoder fault and its associated information
available
Yes
No
-
10
Velocity diagnostics in the Sensor Module
Yes
No
-
11
-
16
Pole position identification
Yes
No
-
17
Burst oversampling
Yes
No
-
19
Safety position actual value sensing
Yes
No
-
20
Extended velocity calculation being used
(only SMC30)
Yes
No
-
21
Zero mark tol
Yes
No
-
22
Rot pos adapt
Yes
No
-
27
SSI position value extrapolation
Yes
No
-
29
Phase correction
Yes
No
-
30
Amplitude correction
Yes
No
-
31
Offset correction
Yes
No
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...