![Siemens SINAMICS S Series Скачать руководство пользователя страница 1493](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_12654271493.webp)
List of faults and alarms
Faults and Alarms
3-1493
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Remedy:
- check the traversing/motion program in the control.
- check the limits for "Safely-Limited Speed (SLS) and if required, adapt (p9531).
This message can be acknowledged as follows:
- motion monitoring functions integrated in the drive: Via Terminal Module 54F (TM54F) or PROFIsafe
- motion monitoring functions with SINUMERIK: Via the machine control panel
Note:
SI: Safety Integrated
SLS: Safely-Limited Speed / SG: Safely reduced speed
See also: p9531 (SI motion SLS (SG) limit values (Control Unit)), p9563 (SI motion SLS (SG)-specific stop response
(Control Unit))
C01745
SI Motion CU: Checking braking torque for the brake test
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
POWER ON (IMMEDIATELY)
Cause:
The normalization of the brake torque for the brake test can be changed using parameter p2003.
An acceptance test must be carried out again for the braking test. This determines whether the braking test is still
carried out with the correct braking torque.
Remedy:
- carry out a POWER ON (power off/on) for all components.
- repeat the acceptance test for the safety brake test if the brake test is used.
See also: p2003 (Reference torque)
A01796 (F, N)
SI Motion CU: Wait for communications to the control
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
NONE
Cause:
The drive waits for communications to be established with the higher-level control to execute the safety-relevant
motion monitoring functions.
Note:
In this state, the pulses are safely deleted.
Remedy:
If, after a longer period of time, the message is not automatically withdrawn, then the following checks are made:
- correct assignment of the axes on the higher-level control to the drives in the drive unit.
- enable signal of the safety-relevant motion monitoring functions for the corresponding axis on the higher-level con-
trol (SINUMERIK).
- check the setting of p9510 (SI motion clock cycle synchronous PROFIBUS master) and if required, set p9510 to 1.
Reaction upon F:
NONE (OFF1, OFF2, OFF3)
Acknowl. upon F:
IMMEDIATELY
Reaction upon N:
NONE
Acknowl. upon N:
NONE
C01798
SI Motion CU: Test stop running
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The test stop is active.
Remedy:
None necessary.
The message is withdrawn when the test stop is ended.
Note:
SI: Safety Integrated
C01799
SI Motion CU: Acceptance test mode active
Drive object:
SERVO, VECTOR
Reaction:
NONE
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The acceptance test mode is active. The POWER ON signals of the safety-relevant motion monitoring functions can
be acknowledged during the acceptance test using the RESET button of the higher-level control.
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...