![Siemens SINAMICS S Series Скачать руководство пользователя страница 901](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427901.webp)
List of parameters
Parameters
1-901
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays the measured sum of the currents in phases U, V and W as peak value.
The summed value of all power units is displayed in r0069[6].
Description:
Displays the measured actual value of the DC link voltage.
The average value of all power units is displayed in r0070.
Description:
Displays the actual voltage, phase U.
The average value of all power units is displayed in r0089[0].
Description:
Displays the actual voltage, phase V.
The average value of all power units is displayed in r0089[1].
Description:
Displays the actual voltage, phase W.
The average value of all power units is displayed in r0089[2].
r7229[0...n]
CO: Par_circuit phase current actual value sum U, V, W / I_phase sum UVW
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
6_5
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
r7230[0...n]
CO: Par_circuit DC link voltage actual value / Vdc_act
A_INF (Parallel),
B_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
5_2
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [V]
- [V]
- [V]
r7231[0...n]
CO: Par_circuit phase voltage actual value phase U / V_phase U act val
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
5_3
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [V]
- [V]
- [V]
r7232[0...n]
CO: Par_circuit phase voltage actual value phase V / V_phase V act val
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
5_3
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [V]
- [V]
- [V]
r7233[0...n]
CO: Par_circuit phase voltage actual value phase W / V_phase W act val
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
5_3
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [V]
- [V]
- [V]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...