![Siemens SINAMICS S Series Скачать руководство пользователя страница 131](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427131.webp)
List of parameters
Parameters
1-131
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
This also applies for parameters for a motor with DRIVE-CLiQ. In this case p0300 can only be set to p0300 = 10000
or 10001 (read motor parameters) or to the corresponding non-Siemens motor (first digit of the motor code number)
in order to be able to cancel the write protection.
Description:
Selects the motor type or start to read-in the motor parameters for a motor with DRIVE-CLiQ (p0300 = 10000 or
10001, if there is a second data set).
The following applies for p0300 < 10000: The first digit of the parameter value always defines the general motor
type and corresponds to the unlisted motor belonging to a motor list:
1 = Rotating induction motor
2 = Rotating synchronous motor
3 = Linear induction motor (reserved)
4 = Linear synchronous motor
5 = Synchronous motor separately-excited
7 = SIEMOSYN motor
8 = Reluctance motor
The type information must be entered to filter motor-specific parameters and to optimize the operating characteris-
tics and behavior. For example, for synchronous motors, power factor (p0308) is neither used nor displayed (in the
BOP/AOP).
Values:
0:
No motor
1:
Induction motor (rotating)
2:
Synchronous motor (rotating, permanent-magnet)
5:
Synchronous motor (separately excited)
7:
SIEMOSYN motor
8:
Reluctance motor
11:
1LA1 standard induction motor
12:
1LE2 standard induction motor (NEMA)
15:
1LA5 standard induction motor
16:
1LA6 standard induction motor
17:
1LA7 standard induction motor
18:
1LA8 standard induction motor
102:
1PH2 induction motor
104:
1PH4 induction motor
107:
1PH7 induction motor
134:
1PM4 induction motor
136:
1PM6 induction motor
166:
1PL6 induction motor
283:
1FW3 synchronous motor
10000: Motor with DRIVE-CLiQ
10001: Motor with DRIVE-CLiQ 2nd data set
Dependency:
Motors, selection 206, 236, 237 cannot be operated (also not as motor with DRIVE-CLiQ).
p0300 = 5 cannot be selected with SINAMICS G.
When the motor type is changed, the code number in p0301 may be reset to 0.
p0300 = 12 can only be selected for p0100 = 1 (NEMA).
When selecting a motor type from the 1LA5 and 1LA7 series, parameters p0335, p0626, p0627 and p0628 of the
thermal motor model are pre-assigned as a function of p0307 and p0311.
Refer to: p0301
Caution:
If a catalog motor is selected (p0300 >= 100) and an associated motor code number (p0301), then the parameters,
that are associated if this list, cannot be changed (write protection). The write protection is canceled if the motor
type p0300 is set to a non-Siemens motor that matches p0301 (e.g. p0300 = 2 for p0301 = 2xxxx).
p0300[0...n]
Motor type selection / Mot type selection
VECTOR
Can be changed:
C2(1, 3)
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
MDS, p0130
Func. diagram:
6310
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 10001
0
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...