List of parameters
Parameters
1-1013
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the time to carry out the forced checking procedure and test the safety motion monitoring functions integrated
in the drives.
Within the parameterized time, the safety functions must have been tested at least once including de-selecting the
function "Safe Torque Off". The monitoring time is reset each time that the test is carried out.
The signal source to initiate the forced checking procedure is parameterized in p9705.
Dependency:
Refer to: p9705
Refer to: C01798
Note:
A change only becomes effective after a POWER ON.
Description:
Sets the shutdown velocity for pulse cancelation.
Below this velocity "standstill" is assumed and for STOP B, the pulses are canceled (by changing to STOP A).
Dependency:
Refer to: p9556
Note:
A change only becomes effective after a POWER ON.
Description:
Sets the shutdown speed for the pulse cancelation.
Below this speed "standstill" is assumed and for STOP B, the pulses are canceled (by changing to STOP A).
Dependency:
Refer to: p9556
Note:
A change only becomes effective after a POWER ON.
Description:
Sets the stop response for the function "Safely-Limited Speed" (SLS).
This setting applies for all SLS limit values.
An input value of less than 5 signifies personnel protection, from 10 and upwards, machine protection.
p9559
SI motion forced checking procedure timer (Control Unit) / SI Mtn dyn timer
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [h]
9000.00 [h]
8.00 [h]
p9560
SI motion pulse cancelation shutdown velocity (Control Unit) / SI Mtn IL v_shutCU
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [mm/min]
6000.00 [mm/min]
0.00 [mm/min]
p9560
SI motion pulse cancelation shutdown speed (Control Unit) / SI Mtn IL n_shutCU
SERVO (Safety rot),
VECTOR (Safety rot)
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [RPM]
6000.00 [RPM]
0.00 [RPM]
p9561
SI motion SLS (SG) stop response (Control Unit) / SI Mtn SLS resp
SERVO, VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 14
5
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...