Dependency:
Refer to: p1141, p1142
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Bit 4 = 0: Inhibits the ramp-function generator (the ramp-function generator output is set to zero)
Bit 4 = 1: Operating condition (the ramp-function generator can be enabled)
Description:
Sets the signal source for control word 1 bit 5 (enables ramp-function generator/ stops ramp-function generator)
Dependency:
Refer to: p1140, p1142
Notice:
The ramp-function generator is, independent of the status of the signal source, active in the following cases:
- OFF1/OFF3.
- ramp-function generator output within the suppression bandwidth.
- ramp-function generator output below the minimum speed.
Note:
Bit 5 = 0: Stop the ramp-function generator (the ramp-function generator output is frozen)
Bit 5 = 1: Enable ramp-function generator
Description:
Sets the signal source for control word 1 bit 5 (enables ramp-function generator/ stops ramp-function generator)
Dependency:
Refer to: p1140, p1142
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Bit 5 = 0: Stop the ramp-function generator (the ramp-function generator output is frozen)
Bit 5 = 1: Enable ramp-function generator
Description:
Sets the signal source for control word 1 bit 6 (enables setpoint/disable setpoint).
Dependency:
Refer to: p1140, p1141
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
Bit 6 = 0: Inhibits the setpoint (the ramp-function generator input is set to zero)
Bit 6 = 1: Enable setpoint
p1141[0...n]
BI: Start ramp-function generator / Start RFG
SERVO, VECTOR
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
2442, 2443,
2501
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
1
p1141
BI: Start ramp-function generator / Start RFG
TM41
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
-
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
1
p1142[0...n]
BI: Enable speed setpoint / Enable n_set
SERVO, VECTOR
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
CDS, p0170
Func. diagram:
2441, 2442,
2443, 2501, 2711
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
1
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...