List of parameters
Parameters
1-699
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note:
The monitoring function is only carried out for separately-excited synchronized motors (p0300 = 5).
The monitoring is only carried out for speeds less than the speed threshold value in p2161 (r2199.0 = 1).
Description:
Sets the delay time for the zero current signal for the zero current monitoring.
Dependency:
Refer to: p3207, p3208
Note:
The monitoring function is only carried out for separately-excited synchronized motors (p0300 = 5).
The monitoring is only carried out for speeds less than the speed threshold in p2161 (r2199.0 = 1).
Description:
Sets the configuration word of the infeed.
Dependency:
Refer to: p0210
Note:
Re bit 00:
In the smart mode, the DC link voltage is not controlled - however, infeed can still regenerate. The magnitude of the
DC link voltage depends on the actual line supply voltage and the DC link load.
For drive units belonging to the 400 V voltage class, for a drive unit supply voltage (p0210) greater than 415 V, the
infeed is always operated in the smart mode. This means that the 660 V limit can be maintained for the steady-state
DC link voltage (p0280) up to a line supply voltage of 480 V.
Re bit 01:
If the flat top mode is deactivated, switching losses are higher. This means that the full power is no longer continu-
ously available.
For p3400.0 = 1, this bit is not effective.
Re bit 03:
If the Vdc controller is switched-out, overvoltage or undervoltage conditions occur in the DC link if no other voltage-
regulating component is located in the DC link.
For p3400.0 = 1, this bit is not effective.
Re bit 05:
VSM: Voltage Sensing Module
If a VSM is detected when commissioning the system, this bit is automatically set.
When the bit is set, the line supply voltage input of the VSM must be connected (connected at the line side of the
commutating reactor).
p3209[0...n]
Zero current signal delay time / I_0_sig t_del
VECTOR
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Messages
Units group:
-
Unit selection:
-
Not for motor type:
ASM, PEM, REL
Expert list:
1
Min Max
Factory
setting
0.00 [s]
10.00 [s]
0.02 [s]
p3400
Infeed configuration word / INF config_word
A_INF, S_INF
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
8940
P-Group:
Closed-loop control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
1010
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Smart Mode
On
Off
-
01
Flat-top mode
On
Off
-
03
Vdc controller
On
Off
-
05
Line supply voltage sensing with VSM
On
Off
-
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...