![Siemens SINAMICS S Series Скачать руководство пользователя страница 523](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427523.webp)
List of parameters
Parameters
1-523
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Displays diagnostics information for the pole position identification routine.
Description:
Sets the current when executing the motion-based pole position identification.
Dependency:
Refer to: p1980, p1982, p1994
Description:
Sets the rise time of the current when executing the motion-based pole position identification.
Dependency:
Refer to: p1980, p1982, p1993
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Critical encoder fault occurred
Yes
No
-
02
Enc parking active
Yes
No
-
05
Encoder fault Class 1
Yes
No
-
06
Encoder fault Class 2
Yes
No
-
07
Pole position identification for encoder car-
ried out
Yes
No
-
08
Fine synchronization carried out
Yes
No
-
09
Coarse synchronization carried out
Yes
No
-
10
Commutation information available
Yes
No
-
11
Speed information available
Yes
No
-
12
Position information available
Yes
No
-
15
Zero mark passed
Yes
No
-
r1992
Pole position identification diagnostics / PolID diag
SERVO (Lin)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Critical encoder fault occurred
Yes
No
-
02
Enc parking active
Yes
No
-
05
Encoder fault Class 1
Yes
No
-
06
Encoder fault Class 2
Yes
No
-
07
Pole position identification for encoder car-
ried out
Yes
No
-
08
Fine synchronization carried out
Yes
No
-
09
Coarse synchronization carried out
Yes
No
-
10
Commutation information available
Yes
No
-
11
Velocity information available
Yes
No
-
12
Position information available
Yes
No
-
15
Zero mark passed
Yes
No
-
p1993[0...n]
Pole position identification current, motion-based / PolID I mot_bas
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_EQU
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [Arms]
20000.00 [Arms]
0.00 [Arms]
p1994[0...n]
Pole position identification rise time motion-based / PolID T mot_bas
SERVO
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
MDS, p0130
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 [ms]
2500 [ms]
100 [ms]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...