![Siemens SINAMICS S Series Скачать руководство пользователя страница 648](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427648.webp)
Parameters
List of parameters
1-648
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the amount of play (backlash) for positive or negative play.
0: The backlash compensation is de-activated.
>0: Positive backlash (normal case)
When the direction is reversed, the encoder actual value leads the actual value.
<0: Negative backlash
When the direction is reversed, the actual value leads the encoder actual value.
Dependency:
If a stationary axis is referenced by setting the reference point, or an adjusted with absolute encoder is powered-up,
then the setting of p2604 is relevant for entering the compensation value.
p2604 = 1:
Traveling in the positive direction -> A compensation value is immediately entered.
Traveling in the negative direction -> A compensation value is not entered
p2604 = 0:
Traveling in the positive direction -> A compensation value is not entered
Traveling in the negative direction -> A compensation value is immediately entered.
When again setting the reference point (a referenced axis) or for "flying referencing", p2604 is not relevant but
instead the history of the axis.
Refer to: p2604, r2667
Description:
Sets the setpoint velocity for jog 1.
Dependency:
Refer to: p2587, p2589, p2591
Description:
Sets the setpoint velocity for jog 2.
Dependency:
Refer to: p2588, p2590, p2591
p2583
EPOS backlash compensation / Backlash comp
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
-
Func. diagram:
3635
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-200000 [LU]
200000 [LU]
0 [LU]
p2585
EPOS jog 1 setpoint velocity / Jog 1 v_set
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
-
Func. diagram:
3610
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-40000000 [1000 LU/min]
40000000 [1000 LU/min]
-300 [1000 LU/min]
p2586
EPOS jog 2 setpoint velocity / Jog 2 v_set
SERVO (EPOS),
VECTOR (EPOS)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
-
Func. diagram:
3610
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
-40000000 [1000 LU/min]
40000000 [1000 LU/min]
300 [1000 LU/min]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...