List of parameters
Parameters
1-975
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the configuration for the encoder and position actual value.
The encoder that is used for the safe motion monitoring functions on the Motor Module must be parameterized in
this parameter.
Dependency:
Refer to: p0404, p0410, p9516
Note:
A change only becomes effective after a POWER ON.
Description:
Sets the grid division for a linear encoder.
The encoder that is used for the safe motion monitoring functions on the Motor Module must be parameterized in
this parameter.
Dependency:
Refer to: p0407, p9316
Note:
A change only becomes effective after a POWER ON.
Description:
Sets the number of encoder pulses per revolution for rotary encoders.
The encoder that is used for the safe motion monitoring functions on the Motor Module must be parameterized in
this parameter.
Dependency:
Refer to: p0408, p9316
Note:
A change only becomes effective after a POWER ON.
p9316
SI motion encoder configuration, safety functions (Motor Module) /
SI Mtn enc_cfg MM
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
0000
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Encoder rotating/linear
Linear
Rotating:
-
01
Position actual value sign change
Yes
No
-
p9317
SI motion linear scale grid division (Motor Module) / SI Mtn grid MM
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0.00 [nm]
250000000.00 [nm]
10000.00 [nm]
p9318
SI motion encoder pulses per revolution (Motor Module) / SI Mtn p/rev MM
SERVO, VECTOR
Can be changed:
C2
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
0 100000
2048
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...