Description:
Displays the deviation between the measured current actual value of phase W and the average value as peak
value.
The maximum deviation from the average value is displayed in r7027.
Dependency:
Refer to: r7020, r7021, r7027
Description:
Displays the maximum absolute deviation of the measured current actual values of phase U from the average value
as peak value.
The deviation of the individual currents from the average value is displayed in r7020.
Dependency:
Refer to: r7020, r7026, r7027
Refer to: A05052
Description:
Displays the maximum absolute deviation of the measured current actual values of phase V from the average value
as peak value.
The deviation of the individual currents from the average value is displayed in r7021.
Dependency:
Refer to: r7021, r7025, r7027
Refer to: A05052
Description:
Displays the maximum absolute deviation of the measured current actual values of phase W from the average
value as peak value.
The deviation of the individual currents from the average value is displayed in r7022.
Dependency:
Refer to: r7022, r7025, r7026
Refer to: A05052
r7022[0...n]
CO: Par_circuit deviation current in phase W / Phase W curr dev
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
PDS, p0120
Func. diagram:
-
P-Group:
Displays, signals
Units group:
6_5
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
r7025
CO: Par_circuit max. deviation currents phase U / Phase U Max i_dev
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Displays, signals
Units group:
6_5
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
r7026
CO: Par_circuit max. deviation currents phase V / Phase V Max i_dev
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Displays, signals
Units group:
6_5
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
r7027
CO: Par_circuit max. deviation currents phase W / Phase W Max i_dev
A_INF (Parallel),
S_INF (Parallel),
VECTOR (Parallel)
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
-
P-Group:
Displays, signals
Units group:
6_5
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [A]
- [A]
- [A]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...