List of parameters
Parameters
1-473
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the speed to change over the motor model for operation with encoder.
Dependency:
Refer to: p1756
Note:
Induction motor (ASM):
The motor model is influenced for speeds/velocities greater than p1752.
Synchronous motor (SRM):
A monitoring (F07412) is activated for speeds/velocities greater than p1752.
The motor model is additionally influenced when kT adaptation is activated (p1780.3 = 1).
Description:
Sets the velocity to change over the motor model for operation with encoder.
Dependency:
Refer to: p1756
Note:
Induction motor (ASM):
The motor model is influenced for speeds/velocities greater than p1752.
Synchronous motor (SRM):
A monitoring (F07412) is activated for speeds/velocities greater than p1752.
The motor model is additionally influenced when kT adaptation is activated (p1780.3 = 1).
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Controlled operation
Active
Inactive
-
01
Set ramp-function generator
Active
Inactive
-
02
Stop RsLh adaptation
Yes
No
-
03
Feedback
Active
Inactive
-
04
Encoder operation
Active
Inactive
-
05
Holding angle
Yes
No
-
06
Acceleration criteria
Active
Inactive
-
07
Set angular integrator PEM
No
Yes
-
08
Stop Kt adaptation PEM
No
Yes
-
09
PolID active PEM SLVC
No
Yes
-
10
I injection PEM
No
Yes
-
11
Speed controller output cannot be set to
zero
Yes
No
-
12
Rs adapt waits
Yes
No
-
13
Motor operation
Yes
No
-
14
Stator frequency sign
Positive
Negative
-
15
Torque sign
Motor mode
Regenerative mode
-
p1752[0...n]
Motor model changeover speed operation with encoder / MotMod n_chgov enc
SERVO
Can be changed:
U, T
Calculated:
CALC_MOD_REG
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
3_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.0 [RPM]
210000.0 [RPM]
210000.0 [RPM]
p1752[0...n]
Motor model with encoder changeover velocity / MotMod v_chgov enc
SERVO (Lin)
Can be changed:
U, T
Calculated:
CALC_MOD_REG
Access level:
3
Data type:
Floating Point
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Closed-loop control
Units group:
4_1
Unit selection:
p0505
Not for motor type:
REL
Expert list:
1
Min Max
Factory
setting
0.0 [m/min]
1000.0 [m/min]
1000.0 [m/min]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...