![Siemens SINAMICS S Series Скачать руководство пользователя страница 638](http://html.mh-extra.com/html/siemens/sinamics-s-series/sinamics-s-series_list-manual_1265427638.webp)
Parameters
List of parameters
1-638
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description:
Sets the signal source for the reference of the internal length units LU to motor revolution for rotary encoders and to
mm for linear encoders.
Dependency:
Refer to: p0404, r2524
Note:
The signal value is used to convert the length unit to the speed or velocity setpoint.
Description:
Displays the position setpoint after the setpoint smoothing.
Description:
Displays the difference between the position setpoint and the position actual value at the position controller input.
Description:
Displays the P component at the output of the position controller for the speed setpoint.
Description:
Displays the P component at the output of the position controller for the velocity setpoint.
p2555
CI: LR LU/revolution LU/mm / LU/rev LU/mm
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
-
Func. diagram:
4015
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- -
2524[0]
r2556
CO: LR position setpoint after setpoint smoothing / s_set after interp
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
-
Func. diagram:
4015
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]
r2557
CO: LR position controller input, system deviation / LR_inp sys dev
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Integer32
Dynamic index:
-
Func. diagram:
4015
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [LU]
- [LU]
- [LU]
r2558
CO: LR position controller output, P component / LR_outp P comp
SERVO (Pos ctrl),
VECTOR (Pos ctrl)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
4015
P-Group:
Closed loop position control
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [RPM]
- [RPM]
- [RPM]
r2558
CO: LR position controller output, P component / LR_outp P comp
SERVO (Lin, Pos
ctrl)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
Floating Point
Dynamic index:
-
Func. diagram:
4015
P-Group:
Closed loop position control
Units group:
4_1
Unit selection:
p0505
Not for motor type:
-
Expert list:
1
Min Max
Factory
setting
- [m/min]
- [m/min]
- [m/min]
Содержание SINAMICS S Series
Страница 1: ...sinamics s SINAMICS S List Manual 07 2007 ...
Страница 2: ......
Страница 1422: ...Function Diagrams Braking Module external 2 1422 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1750: ...Faults and Alarms List of faults and alarms 3 1750 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1778: ...Appendix List for motor code encoder code A 1778 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...
Страница 1812: ...Index D 1812 Siemens AG 2007 All Rights Reserved SINAMICS S List Manual LH1 07 2007 ...